IEC 60331-1 PDF

Purchase your copy of IEC as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards. IEC Tests for electric cables under fire conditions – Circuit integrity – Part 1: Test method for fire with shock at a temperature of at least °C for. IEC / IEC Test method for fire with shock. Test set-up The cable is secured onto a positioning board and a flame is applied.

Author: Arashigar Salkree
Country: Ghana
Language: English (Spanish)
Genre: Business
Published (Last): 15 April 2010
Pages: 313
PDF File Size: 18.37 Mb
ePub File Size: 6.21 Mb
ISBN: 820-9-95714-584-7
Downloads: 2755
Price: Free* [*Free Regsitration Required]
Uploader: Maramar

Annex A provides the method of verification of the burner and control system used for the test.

The maximum change in attenuation a change from zero is recorded during the burner application period. It is divided in following parts that describe the test modes, the isc, and the equipment to use. Related publications IEC The following test report forms are related: Procedures and requirements for fire with shock — Cables of rated voltage up to and including 0.

TC 20 – Electric cables rss. Result 603311-1 the test is considered positive if at that time will not be considered a short circuit in the circuit being researched.

Tests for electric cables for fire conditions and shock- Circuit integrity. It is intended for use when testing cables of greater than 20 mm overall diameter. Circuit insulation Integrity in accordance with IEC IEC specifies tests for electric cable for circuit integrity under fire conditions.

  ANESTEZJOLOGIA CHOMIKUJ PDF

Result of the test is considered positive if at that time will not be considered a short circuit in the circuit being tested. The time of the fire is minutes. IEC ed 1.

Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this document.

Procedures and requirements — Optic Fiber Cables. IEC applies to the cables with a diameter greater than 20mm, and introduces the standards nd procedures for testing of cables exposed to fire and mechanical shock equipment according to The test sample provides cable fragment length at least mm. In the 15 minutes period after the flame application, a maximum attenuation is also recorded.

This second edition cancels and replaces the first edition published in To better simulate the real fire conditions, with mechanical stresses due to the fall of materials and with the presence of water, the testing conditions have been modified by changing the duration, increasing the temperature of the flame and by adding mechanical stresses and water spray.

Fire Resisting Characteristics of Electrical Cables Apparatus

Result of the test is considered positive if at that time will not e considered a short circuit in the circuit being tested. Preview Abstract IEC Our prices are in Swiss francs CHF. Procedures and requirements — Cables of rated voltage up to and including 0. The optical power meter is zeroed and the changes in attenuation during the minutes burner application period are monitored.

  BIOMIMETIC LAYER BY LAYER ASSEMBLY OF ARTIFICIAL NACRE PDF

The significant technical changes with respect to the previous edition are as follows: It constitutes a technical revision. Procedures and requirements — Electric Data Cables.

Bent wire on the U-shaped with a adius equal to the smallest permissible by the manufacturer, is mounted on a metal assay ladder. We accept all major credit cards American Express, Mastercard and VisaPayPal and bank transfers as form of payment.

IEC / IEC Test method for fire with shock

Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC During the study, through all the cable wires is passed current with rated oec and these cables are subjected to fire during min, where fire source is a gas burner set in conformity with standards, as well the echanical shock of the 5 minutes interval.

Do you need a multi-user copy? IEC details a method to assess the circuit integrity of optical fiber cables. Cables of smaller diameter are intended to be tested using the apparatus, procedure and requirements of IEC During the test, to the wire cores of cable a voltage of the nominal value is applied for telecommunication cables equal to Vthereby creating a closed electric circuit.